INFRARED CAMERA WINDOW WITH PIRMA-LOCK

FLIR IR Windows

FLIR IR Windows from Agile Microsys offer a safe solution for inspecting energized electrical systems without risk of arc flash. These windows are equipped with broadband crystal lenses to transmit infrared and visible light. Their PIRma-Lock™ technology ensures easy installation, while the robust construction in anodized aluminum or stainless steel guarantees durability. These windows are designed to meet safety standards and regulatory requirements, including NFPA 70E.

Request Info
BROADBAND TRANSMISSION

FLIR IR Windows’ broadband crystal lenses transmit short, mid, and longwave IR while also allowing illumination to shine through.

PIRMA-LOCK™ RELIABILITY

FLIR’S tried-and-true PIRma-Lock™ locknut technology holds the ring in place so there’s no need for extra screws.

DURABLE STAINLESS STEEL OPTION

Choose the standard anti-corrosion anodized aluminum frame, or if there are mixed-metal concerns, opt for durable stainless steel.

OVERVIEW

Body Material Anodized Aluminum or Stainless Steel AISI 316
Packaging Size 120 x 115 x 40 mm (4.7 x 4.5 x 1.6 in.)
Required Hole Diameter (Nominal) 2-3/8″ (60.3mm)
Warranty Limited Lifetime Warranty Against Manufacturer Defects
Window Thickness 2mm (0.07″)

ENVIRONMENTAL

Maximum Operating Temperature 500°F/260°C
NEMA Environmental Type Type 4/12 (outdoor/indoor)
Optic Maximum Temperature 1355.6°C (2474°F)
Voltage Range Any

IMAGING & OPTICAL

Broadband IR Short Mid & Longwave x
Crystal Insert Diameter 50mm (1.97″)
Greenlee Punch 76BB
Overall Thickness 25.5mm (1.00″)
Picture-in-Picture & Fusion Image Bleeding x
Viewing Aperture Area 1590mm^2 (2.46in^2)
Viewing Aperture Diameter 45mm (1.77″)
Visible Light Spectrum x

MEASUREMENT & ANALYSIS

CSA Certification Product Class 3211 07 x
KEMA [IEC 62271-200] Arc flash test standard: 5kV, 63kA for 30 cycles at 60Hz
Maximum Pullout Strength 657 kg (1450 lbs)
TUV [ANSI – IEEE C37202 section A36] Impact Resistant Cover
TUV [IEC 60068-2-3] 15-day extreme humidity withstand
TUV [IEC 60068-2-6] 100 m/s^2 vibration withstand
TUV [IEC 60529] IP67
UL 50 Environment Type 4/12
Underwriters Laboratories [UL 50V] x

PHYSICAL

Overall Height 85.5mm (3.36″)
Overall Width 73mm (2.87″)